SIDEWALL OUTLETS

Krantz-FA-VT

Krantz Multiplex Outlet FA-VT

ABOUT

For installation in corridor walls of offices, meeting rooms, etc., to provide the occupied zone with supply air spread out into thin single jets.

FEATURES

- Bundles of thin, free single jets
- Jet bundle elements manually rotatable through 360°
- Pronounced spread of supply air jets
- Rapid decrease in jet velocity and temperature difference
- Single-row or double-row arrangement of jet bundle elements
- With connection box for flexible duct connection
- Also usable as return air inlet

Downloads

Krantz-FA-VT-K

Krantz Combined multiplex outlet FA-VT-K

ABOUT

For installation in corridor walls of offices, meeting rooms, etc., to discharge supply air in thin single jets from the lower outlet segment into the occupied zone and to remove return air through the upper outlet segment​.

FEATURES

- Combined supply air and return air outlet
- Generation of jet bundles with thin, free, single supply air jets
- Jet bundle elements manually rotatable through 360°
- Pronounced spread of supply air jets
- Rapid decrease in jet velocity and temperature difference
- Jet bundle elements for supply air and return air respectively arranged in one row
- Return air segment also without jet bundle elements; return air intake via perforated faceplate
- Connection box with supply air and return air spigots for flexible duct connection

Downloads

Krantz-WL

Krantz Linear whirl outlet WL

ABOUT

For mounting on walls or galleries, with nearly horizontal discharge direction, where penetration depths of 4 to 16 m are required.​

FEATURES

- Linear free jet consisting of 5 to 7 single jets, depending on type
- Discharge direction nearly horizontal
- Low sound power level
- 3 sizes for different penetration depths
- Also available with low height for low ceiling plenums
- Connection box for flexible duct connection, or direct connection to main air duct

Downloads

Krantz-DW-V2

Krantz Swivel jet nozzle DW-V2

ABOUT

For installation on walls, pillars or galleries, where adjustment of discharge direction with servomotor or by hand is required.

FEATURES

- Circular free jet
- Discharge direction adjustable through ± 30° around the swivel axis
- Adjustment options: manually, by electric actuator or, without auxiliary energy, by maintenance-free thermostatic control unit
- The thermostatic control unit allows for resetting; the swivel range can be altered in increments of 5°, up to 20˚ in total. The mechanism of the thermostatic control unit is protected from undue application of force by a device that can disengage and engage again when the nozzle is swivelled by hand.
- Position of swivel axis also adjustable in the vertical plane, enabling to alter the discharge direction sideways
- Low sound power level
- Low pressure drop
- Direct connection to supply air duct or pressurized chamber, or connection with push-in end for spiral seam duct and with slip-on end for shaped parts

Downloads

Krantz-DW-V2-DR

Krantz Twist nozzle DW-V2-DR

ABOUT

For installation on walls, pillars or galleries, where adjustment of discharge direction with servomotor or by hand is required.​

FEATURES

- Twist nozzle with small jet penetration depth for air distribution into narrow spaces, with built-on twist element
- Circular free jet
- Discharge direction adjustable through ± 30° around the swivel axis
- Adjustment options: manually, by electric actuator or, without auxiliary energy, by maintenance-free thermostatic control unit
- The thermostatic control unit allows for resetting; the swivel range can be altered in increments of 5°, up to 20˚ in total. The mechanism of the thermostatic control unit is protected from undue application of force by a device that can disengage and engage again when the nozzle is swivelled by hand.
- Position of swivel axis also adjustable in the vertical plane, enabling to alter the discharge direction sideways
- Low sound power level
- Low pressure drop
- Direct connection to supply air duct or pressurized chamber, or connection with push-in end for spiral seam duct and with slip-on end for shaped parts

Downloads

Krantz-DW-N2

Krantz Jet nozzle DW-N2

ABOUT

For installation on walls, pillars or galleries, particularly suitable for rooms with very high acoustic requirements and where the requisite discharge angle can be predetermined.​

FEATURES

- Circular free jet
- Fixed discharge direction
- Extremely low sound power level
- Very low pressure drop
- Direct connection to supply air duct or pressurized chamber, or connection with push-in end for spiral seam duct or with slip-on end for shaped parts

Downloads

Krantz-SW

Krantz Swivel jet outlet SW

ABOUT

For mounting on walls, pillars or galleries, where large penetration depths and high volume flow rates per air outlet are required.​

FEATURES

- Circular, high-turbulence free jet
- Discharge direction adjustable in a plane by ± 20° to the air outlet axis, manually or with servomotor
- Penetration depth adjustable by opening or closing the core tube
- Optional ring insert for very large penetration depths
- Connection to side of main supply air duct or with connection box

Downloads

Krantz-FSG

Krantz Window air curtain unit FSG

ABOUT

Installation in window sills for upward-directed air curtain to compensate for heat transmission by the window when cooling and heating.​

FEATURES

Linear air curtain
Installation in floor or window sill, along the facade
Max. distance to glass pane: 200 mm
Small space required (width 55 mm, height 260 to 310 mm)
With connection box for flexible duct connection

Downloads

Krantz-BF-V

Krantz Broad multiplex outlet BF-V

ABOUT

Installation in the upper area of sidewalls, e.g. in hotel rooms, for spread-out supply air jets and draught-free air distribution.​

FEATURES

- Sidewall air outlet fulfilling the high thermal comfort criteria for commercial applications to EN ISO 7730
- Perforated front plate with built-in nozzle discs in 1-row or 2-row design
- Combined mixing/displacement ventilation system ensuring a high ventilation efficiency in the occupied zone
- The air jets can be spread out as broadly as desired by manually rotating individual nozzle discs by up to 360°
- The broad multiplex outlet may be positioned in the middle or on a side of the room wall (so-called symmetric or asymmetric arrangement)
- Maximum temperature difference between supply and indoor air ±10 K
- Low sound power level and low pressure drop, thus well suited for connection to fan coils

Downloads

Krantz-BL-V

Krantz Parapet outlet BL-V

ABOUT

Installation in window parapets above existing fan coil units. For facade screening when cooling and heating; it also enables the ventilation of workplaces next to the facade.​

FEATURES

- Parapet outlet consisting of a double-row, adjustable induction outlet and a multiplex outlet
- Vertical jet for facade screening and - where required - broadly spread air jet inclined to room for individual workplace ventilation
- No tangential air patterns causing thermal discomfort
- Ideal for replacing simple supply air grilles in window parapets to improve indoor air flow

Downloads

Krantz-WSD

Krantz Wall slot diffuser WSD

ABOUT

For installation in gypsum plasterboard walls.​

FEATURES

- With 1 or 2 rows for supply air or return air or both combined
- Slot element easy to remove thanks to push-in connection; thus cleanable as per VDI 6022
- Connection box to be installed inside or behind gypsum plasterboard walls; volume flow damper adjustable from room (optional)
- High level of thermal comfort: max. cooling capacity up to 120 W/m²
- High insertion loss with abrasion-resistant acoustic lining of class A2 as per DIN 4102-1 (optional); this obviates the need for crosstalk silencers

Downloads

  • Twist Outlet DD-N
  • Radial Slot Outlet RL
  • Radial Slot Outlet RLC
  • Radial Outlet RA-N
  • Radial Outlet RA-N2
  • Radial Outlet RA-N3
  • Adjustable Radial Outlet RA-V
  • Adjustable Radial Outlet with core tube RA-V2
  • Microdrall MD
  • Variable Twist Outlet with core tube DD-VK
  • Variable Twist Outlet with guide ring DD-VL
  • Variable Twist Outlet with jet straightner DD-VG
  • Temperature Difference Control Device ST-E
  • Induction Outlet with present discharge direction IN-N6
  • Adjustable Induction Outlet IN-V
  • Opticlean OC-Q
  • Circular Opticlean OC-R

ON TWITTER
STAY IN TOUCH WITH OUR LATEST DEVELOPMENTS
Must be an email address
Thank you! Your submission was successfully sent :-)×
Opps! Some went wrong... Your submission did not go through :-(×